ASTM roofing felt

ASTM roofing felt
Product Detailed
Roofing paper is a underlay of asphalt shingle over roof deck. Sencondary barrier to moisture caused by wind-driven rain .

                                    Roofing paper

Description:

This roofing paper(ASTM D-226 ,ASTM D-4869 ) is made of a specially formulated organic sheet which has been fully saturated with waterproofing asphalt.

Uses:

A roofing paper used as an underlay beneath asphalt shingles, wood shakes, tiles and other sloped coverings.

Physical Requirements:

                  Test Item

                ASTM D-226 I

                 ASTM D-226 II

                 ASTM D-4869 I

                  ASTM D-4869 II

               Pliability at 23±2°C. 

    Tested shall not crack when bent 90

  at a uniform speed over a roundedcorner 

      of radius in table for each type.

   12.7mm

    (radius)

    19.1mm

     (radius)

      12.7mm

       (radius)

      12.7mm

       (radius)

        Tear strength at 23±2°C min,

      2.5N

       5.0N

       2.0N

        3.0N

          Breaking strength at 23±2°C, 

                      min MD

    30 lbf/in

    40 lbf/in

      30 lbf/in

     40 lbf/in

      Breaking strength at 23±2C,    

                     min CD

    15 lbf/in

    20 lbf/in

     15 lbf/in

     20 lbf/in

    Loss on heating at 105°C for 5h max

     4.0%

      4.0%

        6.0%

       6.0%

                Width of the roll

      36 in

       36 in

        36 in

       36 in

                 Area of the roll

      432 ft²

      216 ft²

        432 ft²

       216 ft²

        Net mass of saturated felt, min

    560 g/m²

    1270g/m²

     400 g/m²

     660 g/m²

             Saturation,% by wt., min

      120%

      150%

       100%

     120%

Storage and Handling 

Roofing paper require protection from damage and the weather. 

Store rolls upright in a dry location and never install when wet or over a wet roof deck.

ASTM roofing felt



Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.